Application of Continuous Emission Monitoring System for Fuel Gas from Stationary Pollution Sources to Incineration of Industrial Hazardous Wastes
Abstract:The composition of continuous emission monitoring system (CEMS) for fuel gas from stationary pollution sources is introduced,and the measurement methods are compared. The practical application of CEMS to incineration system of industrial hazardous wastes is discussed. The operators can real-timely know the flue gas emission to improve the incineration efficiency of industrial hazardous wastes and the treatment efficiency of flue gas,save energy source and raw materials and ensure that the emission indexes of harmful gases arising from incineration of industrial of industrial hazardous wastes meet the national standard.
Key words:industrial hazardous waste;incineration;stationary pollution source;continuous emission monitoring system for fuel gas
① 干法抽取法。優(yōu)點(diǎn)為:是已被證實(shí)可靠的技術(shù);大多數(shù)分析儀制造商均采用這種方法;測量精度較高。缺點(diǎn)為:由于采用干基測量,需要采用其他方法確定煙氣的濕度,以計(jì)算煙氣的質(zhì)量流量;在高硫分場所,存在酸冷凝的可能;樣氣處理設(shè)備需要經(jīng)常維護(hù);需要大量的干燥用氣;使得運(yùn)行費(fèi)用較高、取樣流量較大,減短了過濾器的使用壽命。
② 完全抽取法。優(yōu)點(diǎn)為:是已被證實(shí)可靠的技術(shù);能直接測量煙氣的濕度;分析儀維修量小。缺點(diǎn)為:需配置伴熱管道、耐熱分析儀;煙氣的濕度會影響氮氧化物的測量精度;制造廠家較少;取樣流量較大,過濾器的使用壽命較短。
③ 稀釋抽取法。優(yōu)點(diǎn)為:是已被證實(shí)可靠的技術(shù);分析儀維修量??;不需要伴熱管道;樣氣流量低;過濾器的使用壽命長;制造廠家較多。缺點(diǎn)為:需要修正壓力和溫度條件的變化;為保證測量的準(zhǔn)確,清潔干燥空氣需進(jìn)行凈化處理;需要經(jīng)常對取樣管道進(jìn)行防凍處理,并對探頭加熱。
① MCS100E型煙氣分析儀采用單光束雙波長紅外光度計(jì),并運(yùn)用氣體濾波技術(shù),可同時(shí)測量多個(gè)氣體組分,并對干擾組分進(jìn)行自動(dòng)補(bǔ)償。該煙氣分析儀由取樣系統(tǒng)、系統(tǒng)機(jī)柜組成。取樣系統(tǒng)包括:帶加熱過濾器的高溫取樣探頭及適合高溫條件運(yùn)行的測量、吹掃、校準(zhǔn)閥組和伴熱取樣管道;系統(tǒng)機(jī)柜內(nèi)安裝高溫測量系統(tǒng),包括配置高溫測量氣室的紅外光度計(jì)、高溫取樣泵、高溫流量計(jì)、伴熱樣氣傳輸管道。這種結(jié)構(gòu)設(shè)計(jì)可保證所有與氣體接觸的組件溫度均高于煙氣的酸露點(diǎn),不被腐蝕。
② GM-700型可調(diào)諧二極管激光分析儀的測量原理是利用單線激光光譜測量氣體濃度,可調(diào)諧二極管激光吸收光譜(TDLAS)技術(shù)利用二極管激光器的波長調(diào)諧特性,獲得待測氣體的特征吸收光譜,從而對氣態(tài)污染物進(jìn)行定性或者定量分析。該分析儀直接安裝在煙囪上,用于測量煙氣中HF的含量。
③ FW300型煙塵分析儀采用光透射原理,當(dāng)可控光源穿過帶有微小顆粒的氣體時(shí),高靈敏傳感器可檢測出被微小顆粒吸收的光能,并將其與參比光進(jìn)行比較從而確定透射值或濁度值,再進(jìn)一步得出煙塵含量。FW300型煙塵分析儀具有以下特點(diǎn):以光學(xué)技術(shù)為基礎(chǔ),自動(dòng)完成測量、控制、線性測試及污染物檢測功能,反應(yīng)速度快、無采樣處理過程;帶有吹掃裝置,可防止光學(xué)鏡頭面受污染;具備快速切斷閥,可在吹掃裝置失效后自動(dòng)保護(hù)儀器;安裝簡便,發(fā)射與檢測單元可通過法蘭安裝在煙道兩側(cè);含塵量的測量僅與煙道直徑有關(guān),與煙氣流速、濕度和顆粒的性質(zhì)無關(guān);多種信號輸出和顯示,可滿足各類測量、控制與系統(tǒng)集成要求。